SysLink-IPC: Samples - Start Notify samples from event 5
authorJuan Gutierrez <jgutierrez@ti.com>
Fri, 10 Dec 2010 06:15:59 +0000 (00:15 -0600)
committerSuman Anna <s-anna@ti.com>
Fri, 24 Dec 2010 22:29:12 +0000 (16:29 -0600)
commit888e4b1f765886eefa06add4dd83710efc123923
tree85fb185b71b17cbadf160bba6e66b4e5de3febe0
parent1e29e76283841de02e0d0d8d4b2a3cd7b56bd78d
SysLink-IPC: Samples - Start Notify samples from event 5

The IPC code uses the first 5 notify events for internal notifications.
The current Notify samples register event 4 from the application, and as
such the application is inadvertently notified when the devh module sends
event 4. This patch updates all starting event number in the Notify
and InterM3 samples to 5

Signed-off-by: Juan Gutierrez <jgutierrez@ti.com>
packages/ti/omap/samples/interM3/interM3_0.c
packages/ti/omap/samples/interM3/interM3_1.c
packages/ti/omap/samples/notify/Notify_MPUAPP_reroute_Test_Core1.c
packages/ti/omap/samples/notify/Notify_MPUSYS_Test_Core0.c
packages/ti/omap/samples/notify/Notify_MPUSYS_reroute_Test_Core0.c