OMAP3+: Voltage: add ABB to voltage scaling
authorMike Turquette <mturquette@ti.com>
Thu, 21 Jul 2011 10:36:37 +0000 (12:36 +0200)
committerJason Kridner <jdk@ti.com>
Sat, 3 Sep 2011 21:57:03 +0000 (17:57 -0400)
commitcff7af5d9df8dc249736094eb3a1d8c094bce393
tree2e570b614d89301075155eb53ec26383497b5cb7
parent69cd0a8d25262d1b5acfb44a2c1567b18ba8467d
OMAP3+: Voltage: add ABB to voltage scaling

Adaptive Body-Bias ldo state should be transitioned (if necessary) after
a voltage scaling sequence completes via vc_bypass or vp_forceupdate
methods.

This patch initializes the ABB ldo's as a part of the greater voltage
initialization function and adds the ABB transition routine to both the
vc_bypass and vp_forceupdate sequences.

Signed-off-by: Mike Turquette <mturquette@ti.com>